# TBOM

> How to properly install the Denowatts back-of-the-module temperature sensor (TBOM). This was previously covered at a top level in the POA Deno section; however, more details will be provided here.

Source: https://docs.denowatts.com/hardware/current-deno-hardware/deno-sensor-setup/installation/auxillary-sensors/tbom

How to properly install the Denowatts back-of-the-module temperature sensor (TBOM). This was previously covered at a top level in the POA Deno section; however, more details will be provided here.

The Tbom (Back-of-Module temperature) Sensor is critical in assuring an accurate benchmark.

## Terminations

**The Tbom sensor is labeled in the picture below**

![](https://docs.denowatts.com/media/01M3Y4A665ADYPBVXZKJMZW3R0-back-of-deno-2025-494fa3ca786b892c53ff391b403e7ced.webp)

![](https://docs.denowatts.com/media/01M3Y4BAWV130GGMRNYD8HE7SX-t3facedown-65de112a5ef29dad60b4fec1756225d7.webp)

**Please check that the Tbom wiring terminations correspond with the image of the Tbom terminals below.**

![AuxTerm](https://docs.denowatts.com/media/01M3Y48BGWZFD3CPC5C6X39VTF-4-3-aux-sensor-wiring-b174dbf31a3153c3c968baeee1a3cfba.webp)

Use the image above to replace an old Tbom on a Deno 4.2 or 4.3. If you are servicing a tbom on Deno models 4.0 and 4.1, use the image below.

![AuxTerm](https://docs.denowatts.com/media/01M3Y49QF8HYE8RC02F4C0JG67-image-backpanel4-0-9f6823e8f39ef31e03883d2d84d5619b.webp)

## Installation Steps

### 1\. Locate Sensor

Locate the back of the module temperature sensor on the back of the solar module, approximately 24" from the frame.

- **Ensure that the sensor tip is located in the middle of a PV cell**
- **Ensure that the sensor is not at the end of a row**

### 2\. Clean Mounting Location

Clean the Tbom location with the provided alcohol prep pad and **completely dry it with a cloth.**

### 3\. Apply Dual Lock !! IMPORTANT !!

Separate the Dual-Lock and apply one side to the back of the panel, ensuring the entire surface is adhered to the module.

  
\*\*\*\*It is imperative that one side of the dual lock is applied to the module first; If the Dual-Lock is mated together, separate the two sides before applying to the module. Do not apply the entire fixture at once; it will not adhere properly\*\*\*\*

### 4\. Fasten Tbom

Fasten the Tbom mechanism using the dual-lock mating piece that was just attached to the panel in step 3.

### 5\. Wire Management

Tidy up any remaining cable with zip ties and wire clips, keeping the wire away from sharp edges, moving tracker parts, and DC homerun cables.

### 6\. Pictures

Please document the entire installation with several photos

## Example Install Pictures

**The graphic below shows that the Tbom is mounted at least 1 module from the end of the row and 24" away from the module frame.**

![tbom](https://docs.denowatts.com/media/01M3Y4A80ADPGFBDS25X7XCN5C-northside-aux-sensors-bc8016117370f7e416454154cc9e7e06.webp)

**Below are images of examples of Tbom installations. The sensor tip is correctly located in the middle of a PV cell, the wire goes around the sensor in a horseshoe shape, and the cables are appropriately managed.**

![](https://docs.denowatts.com/media/01M3Y4BMG08KYXW0GCADJ5DHE5-t3-installation-15b06df72aeffc52ef47f303bbf39e5e.webp)

![](https://docs.denowatts.com/media/01M3Y4BH9Q4QXM36Y3CKXQ397W-t3-installation2-2ba0860763ec30a6d68ea44adedbb862.webp)

---

**Please contact Denowatts at any point while reading this guide with questions, comments, or concerns:**

- By Phone: 978.309.6688 x1
- Email: [support@denowatts.com](mailto:support@denowatts.com)
- Check out the [**Denowatts Support Center**](https://support.denowatts.com/) for more articles that dive deeper into our methodology and software.